  • ATOMIC ABSORPTION SPECTROPHOTOMETER ( AAS ) , RAYLEIGH WFX-110A/ 120A/ 130A

ATOMIC ABSORPTION SPECTROPHOTOMETER ( AAS ), RAYLEIGH WFX-110A/ 120A/ 130A

Update Terakhir
:
17 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
91 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail ATOMIC ABSORPTION SPECTROPHOTOMETER ( AAS ), RAYLEIGH WFX-110A/ 120A/ 130A

WFX-110A/ 120A/ 130A Flame/ Graphite Furnace Atomic Absorption Spectrophotometer ( AAS ) Manufacturer : RAYLEIGH ISO 9001: 2000 & ISO 4001: 2004 CE-TUV GmbH Features: 1 Innovated rich oxygen air-acetylene flame analysis technique ( WFX-110A ) : The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temperature is continuously adjustable between 2300-2950¡ æ , with makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame will not pollute the environment and is not harmful to human bodies. It' s break-through in flame AAS analysis 2 Integrated flame/ graphite furnace atomization system, changeable with flame emission burner 2.1 Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor 2.2 A flame emission burner head can be installed to perform flame emission analysis to alkali metals as K, Na etc. ( WFX-110A/ 120A ) 3 Accurate fully automated control system 3.1 Automatic multi-lamp turret, automatic adjustment of lamp current and optimization of light beam position 3.2 Automatic wavelength scanning and peak picking 3.3 Automatic spectral bandwidth changing 3.4 Automatic changeover between flame and graphite furnace operation, automatic optimization of position parameters and automatic ignition 4 Reliable fully automatic graphite furnace analyses 4.1 Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature control accuracy is less than 1% 4.2 Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact 5 Perfect safety protection measures 5.1 Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system 5.2 Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling water supply and over-heating in graphite furnace system 6 Advance and reliable electronic design 6.1 Adopting large-scale programmable logic array and Inter I2C bus technology 6.2 European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system 7 Easy and practical analysis software 7.1 Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization 7.2 Automatic sample dilution, automatic curve fitting, automatic sensitivity correction Main Specification Wavelength range 190-900nm Wavelength accuracy Better than ¡ À 0.25nm Resolution Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30% . Baseline stability 0.004A/ 30min Background correction The D2 lamp background correction capability at 1A is better than 30 times The S-H background correction capability at 1.8A is better than 30 times.( only for WFX-110A/ 120A Hollow Cathode Lamps Lamp turret 6-lamp turret ( WFX-110A/ 120A ) , 4-lamp turret ( WFX-130A ) ; Auto-alignment, fully automated scan and peak-picking. Lamp current adjustment 400Hz square wave pulse Wide pulse current: 0~ 25mA, Narrow pulse current: 0~ 10mA Lamp power supply mode 400Hz square wave puls 100Hz narrow square wave pulse+ 400Hz wide square wave pulse ( WFX-110A/ 120A ) Optical System Monochomator Single beam, Czerny-Turner design grating monochromator Grating 1800 l/ mm Focal length 277mm Blazed Wavelength 250nm Spectral Bandwidth 0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change Flame Atomizer Burner 10cm single slot all-titanium burner Spray chamber Corrosion resistant all-plastic spray chamber Nebulizer High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7ml/ min Emission burner provided with WFX-110A/ 120A Graphite Furnace Temperature range Room temperature~ 3000º C Heating rate 2000pC/ s Graphite tube dimensions 28mm( L) x 8mm( OD) Characteristic mass Cd¡ Ü 0.5 ¡ Á 10-12g, Cu¡ Ü 5 ¡ Á 10-12g, Mo¡ Ü 1¡ Á 10-11g Precision Cd¡ Ü 3% , Cu¡ Ü 3% , Mo¡ Ü 4% Detection and Data Processing System Detector R928 Photomultiplier with high sensitivity and wide spectral range Software Windows operating system Analytical method Working curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content. Repeat times Maximum 20 times of repeat measurement, automatic calculation of mean value, standdard deviation and relative standard deviation. Multi-task Functions Sequential measurement for multi-element determination in one sample Condition reading With model function Result printing Measurement data and final analytical report printout, editing with Excel Standard RS-232 serial port communication Characteristic Concentration and Detection Limit Normal Air-C2H2 flame Cu: Characteristic concentration¡ Ü 0.025mg/ L, Detection limit¡ Ü 0.006mg/ L; Oxygen-rich Air-C2H2 flame Ba: Characteristic concentration ¡ Ü 0.22mg/ L, Al: Characteristic concentration ¡ Ü 0.4mg/ L ( for WFX-110A ) Function Expansion Hydride vapor generator can be connected for hydride analysis Dimensions and weight Main unit 102¡ Á 49¡ Á 54cm, unpacked 80kg Graphite furnace 42¡ Á 42¡ Á 46cm, unpacked 50kg
Tampilkan Lebih Banyak